Skip to content
Made in Poland
Global Shipping
Tutorials & Guides

Frequency Response

1 Introduction

Frequency Response measures how a motion platform follows a sine wave on one axis as the frequency rises: how much of the requested stroke it performs and how far it lags behind the command. The result is the bandwidth of the platform on that axis: the figure a data sheet or a simulation study needs, measured on the real machine with its real load.

The tool runs a stepped sine sweep: one frequency at a time, from slow to fast, each held long enough to be measured. Two things are read while it runs:

  • Actuator feedback - the positions the actuators report. This shows what the drives did. It is always available.
  • Top frame (LMD) - the motion of the top frame itself, read by a Latency Measurement Device (LMD) placed on it. This shows what the seat received, including everything the mechanics add: flex, play and resonance. It is optional.
Information
The actuator feedback has limits. The platform reports the actuator positions about every 10 ms, and each report says how old the position is, so the tool knows the moment of every reading to about one millisecond. One millisecond is a small error at low frequency, but at 10 Hz it is 3.6 degrees of the cycle. The ratio is therefore reliable at every frequency, while the lag taken from the feedback is reliable only up to about 3 Hz. The feedback also comes from the actuator's encoder, not from the seat. Play or flex between the two does not show in this column. Use the top-frame columns for the lag at higher frequencies and for the motion the seat actually receives.

The tool is in Tools and Diagnostic. It is available in the Motion Systems edition of ForceSeatPM.

Warning
The platform moves on its own for a few minutes, faster and faster, up to the amplitude you allow. Make sure nobody is sitting on it and that the area around it is clear before you start.

2 Before you start

  1. Have the platform's data sheet at hand. The sweep stays within the velocity and acceleration limits you enter for the axis, and the measurement cannot start until they are entered.
  2. If you want the top-frame columns, connect the LMD to USB and mount it flat on the top frame, its x axis pointing forward, y to the left and z up. The page says whether an LMD was found.
  3. Your motion profile is switched off while the page is open and comes back when you leave it.

3 Running a measurement

  1. Pick the platform (when two are connected), the axis and the sweep:
    • Quick runs 0.2 to 4 Hz in six steps, about a minute and a half.
    • Full runs 0.1 to 10 Hz in thirteen steps, about three minutes.
  2. Enter the limits of the platform under test for that axis: its maximum velocity and acceleration from the data sheet, in the axis' unit (deg/s and deg/s² for a rotation, mm/s and mm/s² for a translation), and the share of the axis range that the slowest step may use (50 % by default). The values are remembered for this platform and axis in this browser.
  3. Next to Start, the page shows how long the run will take and the amplitude of every step. If some steps of the preset are left out, a notice says which and why (see Steps left out below).
  4. Press Start. During the run, the page shows the current step, the ratio and lag of the step that has just finished, and a live plot of the commanded and the reported position.
  5. Stop brings the platform smoothly back to the centre and keeps the steps measured so far. Leaving the page asks for confirmation first and then does the same.
Information
During a run, the commands sent to the platform use its full speed and the rapid ramp. The tool measures the platform itself, not a speed limit or a ramp that a motion profile would normally request.

4 Reading the results

Every step has two numbers per source:

  • Ratio - the measured stroke divided by the commanded stroke. 1 means the platform made the full stroke, 0.7 means it made 70 % of it. The same number in decibels is next to it: 1 is 0 dB, 0.707 is -3 dB.
  • Lag - how far the measured motion is behind the command, as a share of the cycle in degrees (a quarter of a cycle is -90°) and as time in milliseconds. A negative angle is a lag, a positive one would be a lead.

The summary above the chart gives the two frequencies that a data sheet quotes:

  • -3 dB at - the frequency where the ratio falls below 0.707, the usual definition of bandwidth.
  • -90 degrees at - the frequency where the lag reaches a quarter of a cycle.

Both are interpolated between the two steps around the crossing, on the logarithmic frequency axis. not within the sweep means the crossing did not happen: the curve stays above -3 dB (or above -90°) up to the last step.

The chart plots the ratio and the lag against frequency, the actuator feedback in blue and the top frame in green, with the -3 dB and -90° guides dashed in orange. Move the pointer over either panel to read the values of the nearest step. The same step is marked in both panels.

Tip
The feedback columns come from the drive encoders, reported every 10 ms and timed to about a millisecond, so their lag is accurate to a few degrees up to about 3 Hz and less accurate above that (see the limits in the introduction). The top-frame columns come from the LMD, which samples at 8 kHz, keeps its own clock and holds its timing across the whole sweep. Above a few hertz, quote those.

4.1 Steps left out

At high frequency the acceleration limit decides the amplitude: with a as the limit and f the frequency, the stroke is a / (2πf)². With a small limit, the fast steps would have a stroke too small for the feedback to resolve (under 0.1 mm or 0.006°), so the plan leaves them out instead of measuring noise. The page says so before you start and names the first affected frequency. A larger acceleration limit brings the steps back.

4.2 Other numbers

  • Ratio at the slowest step - should be close to 1. If it is not, the platform does not reach the requested stroke even at low frequency, for example because of a range limit, a parked axis or a profile that is still active.
  • Frames the platform refused - commands the platform could not reach. A few near the limits are harmless, many mean the amplitude share is too large.
  • Mean position age - how old the reported positions were when they arrived. The tool subtracts this age from their time stamps.
  • LMD frames and the channel used (for example gyro x for roll, acc z for heave).
  • Limits entered and Sweep - the settings the run was measured with.
Information
If the top-frame lag is close to ±180° at every step, the LMD is mounted backwards: turn it so that its x axis points forward.

5 Method

The symbols used below:

fthe frequency of the step, in hertz
Rthe axis' range, the smaller of its two excursions from centre
sthe amplitude share you entered (50 % is 0.5)
v, athe velocity and acceleration limits you entered
A, φthe amplitude and the phase of a fitted sine

5.1 1. The amplitude of a step

The amplitude is the smallest of three limits, so the sweep never requests more than the platform is rated for:

A(f)= min( R⋅s, v2πf, a(2πf)2 )

The three are the swing you allowed, the stroke whose peak velocity equals v, and the stroke whose peak acceleration equals a. A step whose amplitude falls below 0.1 mm (0.006°) is left out of the plan.

5.2 2. The timing of a step

The sine ramps up over one period, settles for two periods, is measured over whole periods (at least three periods and at least three seconds), then fades out and pauses for one second before the next step.

5.3 3. The fit

Over the measured periods, a sine of the step's frequency is fitted by least squares to each recorded series: the command, the feedback and the top frame. The command is fitted too, so a late or irregular frame is measured rather than assumed:

y(t)= A⋅sin(2πft+φ)+c

5.4 4. Ratio and lag

ratio= AmeasuredAcommand ratiodB= 20⋅log10(ratio) lag= φmeasured−φcommand lagms= −lagdeg360⋅f⋅1000

A negative lag means the measured motion is behind the command.

5.5 5. The top frame

The LMD measures acceleration for a translation and angular velocity for a rotation, not position. A stroke A at frequency f has an acceleration amplitude of A(2πf)² and a velocity amplitude of A·2πf, so the stroke is recovered from the fitted amplitude, and the half turn (acceleration) or quarter turn (velocity) of phase that the derivative adds is removed:

Aframe= afit(2πf)2 , φframe=φfit−π (translation) Aframe= ωfit2πf , φframe=φfit−π2 (rotation)

5.6 6. Time stamps

A reported position is placed at the moment the drive read it: the arrival time minus the age the platform reports with it. An LMD frame carries the device's own clock. Over the run a straight line is fitted between that clock and the computer's, and every LMD window is placed on that line, so the LMD samples keep their timing regardless of the length of the sweep.

5.7 7. The two frequencies

The -3 dB frequency is where the ratio first drops below 1/√2 = 0.707, the -90° frequency is where the lag first reaches a quarter of a cycle. Both are interpolated between the two steps around the crossing, on the logarithmic frequency axis.

6 Saving the results

Save as CSV writes two files. The file you name holds the results table with one row per step: frequency, amplitude, feedback ratio and phase, frame ratio and phase, then the axis, unit, sweep, the limits entered, the mean position age, the LMD frame count and channel, and the refused frames. These values are repeated in every row so that the file reads as a single table. A second file named <name>-samples.csv holds the raw series as series, t_s, value, where the series is command, feedback or frame, for anyone who wants to analyse them differently.